Part Number Hot Search : 
OPB608C LT0412 NTE92 LANCW3 SSP60 P2600SB 1N415 5562A
Product Description
Full Text Search
 

To Download G3CN Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Solid-state Relay
PCB-mounting SSR for FA Equipment Requiring High Reliability
Wide I/O voltage range: 3 to 28 VDC input and 75 to 264 VAC output or 3 to 28 VDC input and 3 to 52.8 VDC output. Two load currents available: 2 A and 3 A Flat and vertical models available for a variety of applications. Approved by UL and CSA.
G3CN
RC Ordering Information
Isolation Photocoupler Zero cross function Yes Indicator No Rated output voltage (Applicable output load) 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) Phototriac No 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) Photocoupler --2 A at 4 to 48 VDC (2 A at 3 to 52.8 VDC) 3 A at 4 to 48 VDC (3 A at 3 to 52.8 VDC) *Vertical models. **When ordering, specify the input voltage 4 to 24 VDC 5, 12, 24 VDC** Rated input voltage 4 to 24 VDC Model G3CN-202P-US G3CN-202P1-US* G3CN-203P-US G3CN-203P1-US* G3CN-202PL-US G3CN-202PL1-US* G3CN-203PL-US G3CN-203PL1-US* G3CN-DX02P-US G3CN-DX02P1-US* G3CN-DX03P-US G3CN-DX03P1-US*
171
G3CN
G3CN
Specifications
Ratings
Input
Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage G3CN-202P(1)-US G3CN-203P(1)-US G3CN-202PL(1)-US G3C 0 ( ) US G3CN 203PL(1) US G3CN-203PL(1)-US 4 to 24 VDC 5 VDC 12 VDC 24 VDC G3CN-DX02P(1)-US G3CN-DX03P(1)-US Note: 4 to 24 VDC 3 to 28 VDC 4 to 6 VDC 9.6 to 14.4 VDC 19.2 to 28.8 VDC 3 to 28 VDC 1.5 k +20%/-10% 390 20% 900 20% 2 k20% 1.5 k +20%/-10% 3 VDC max. 4 VDC max. 9.6 VDC max. 19.2 VDC max. 3 VDC max. Must release voltage 1 VDC min.
The input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the input impedance is measured at 28 VDC.
Output
Model Rated load voltage G3CN-202P(1)-US G3CN-202PL(1)-US G3CN-203P(1)-US G3CN-203PL(1)-US G3CN-DX02P(1)-US G3CN-DX03P(1)-US 4 to 48 VDC 3 to 52.8 VDC 100 to 240 VAC Applicable load Load volage range 75 to 264 VAC Load current Without heat sink 0.1 to 2 A 0.1 to 3 A 0.1 to 2 A 0.1 to 3 A 30 A (60 Hz, 1 cycle) 45 A (60 Hz, 1 cycle) 12 A (10 ms) 18 A (10 ms) Inrush current
Characteristics
Item Operate time Release time Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient humidity Approved standards Weight G3CN-202P(1)/203P(1)-US 1/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. 1.6 V (RMS) max. 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) 100 M min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Malfunction: 1,000 m/s2 Operating: -30C to 80C (with no icing nor condensation) Storage: -30C to 100C (with no icing nor condensation) Operating: 45% to 85% UL508, UL114 File No.E64562, CSA C22.2 (No.0, No.14) File No. LR35535 Approx. 25 g 2.5 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) G3CN-202PL(1)/203PL(1)-US 1 ms max. 1/2 of load power source cycle + 1 ms max. G3CN-DX02P(1)/03P(1)-US 0.5 ms max. 2 ms max. 1.5 V max. 5 mA max. (at 50 VDC)
172
G3CN
G3CN
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3CN-202P(1)/-202PL(1)/-DX02P(1)-US G3CN-203P(1)/-203PL(1)/-DX03P(1)-US
Load current (A)
Ambient temperature (C)
Load current (A)
Ambient temperature (C)
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3CN-202P(1)/-202PL(1)-US G3CN-DX02P(1)-US
Inrush current (A. Peak)
Energizing time (ms)
Inrush current (A. Peak)
Energizing time (ms)
G3CN-203P(1)/-203PL(1)-US
G3CN-DX03P(1)-US
Inrush current (A. Peak)
Energizing time (ms)
Inrush current (A. Peak)
Energizing time (ms)
173
G3CN
G3CN
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Flat Model
G3CN-20jP/-20jPL/-DX0jP
33 max.
25 max.
Terminal Arrangement/ Mounting Holes (Bottom View)
Four 1.2-dia. holes 25 Two, 4 dia. holes
10 14.5 20 max. max. 1.5 max. Two, 2-dia. holes 0.4 250.5 0.7 100.5 12.50.5 + Input voltage - 3 + Input - 4 Load (-) 2 0.7
12.5
Terminal Arrangement/ Internal Connections (Bottom View)
1 (+) Load power supply (-) Load (+)
Vertical Model
G3CN-20jP1/-20jPL1/-DX0jP1
33 max.
Note:
Values in parentheses apply to the DC-load versions.
14 max.
Terminal Arrangement/ Mounting Holes (Bottom View)
Two, 2-dia. holes Four 1.2-dia. holes
Pattern 5 26.5 max. 32 max. 1.5 max. (17.5) 27.5 5
Pattern
Terminal Arrangement/ Internal Connections (Bottom View)
(17.5) 27.50.5 0.7 50.5 0.4 31 Input voltage - + Load power supply (-) (+) Load
50.5
4 -
3 + Input (-)
21 (+) Load
Note:
Values in parentheses apply to the DC-load versions.
174
G3CN
G3CN
Precautions
Refer to pages 11 to 19 for general precautions.
Connection
With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR.
Protective Component
Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K063-E1-2A
175


▲Up To Search▲   

 
Price & Availability of G3CN

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X